| | | Pole:2,3,4Rated voltage (Un): 230(240)/400(415)V AC, max. 60V DCRated current (In): 0.5-63A Rated frequency (Fn):50Hz Rated breaking capacity:10KA Energy limiting class:3 Tripping characterisic:B,C,D Cross-section of connecting lead:1-25mm2 Isolating class:BMounting on the rail:EN50022 Built-in width:18mm/poleStandard: IEC60898, EN60898 China | | | | | TECHNICAL DATA
Pole:2,3,4
Rated voltage (Un): 230(240)/400(415)V AC, max.60V DC
Rated current (In): 0.5-63A
Rated frequency (Fn):50Hz
Rated breaking capacity:10KA
Energy limiting class:3
Tripping characteristic: B,C,D
Cross-section of connecting lead:1-25mm²
Isolating class: B
Mounting on the rail:EN50022
Build-in width:18mm/pole
Standard: IEC60898, EN60898
Packing: CTN China | | | | | TECHNICAL DATA
Pole:2,3,4
Rated voltage (Un): 230(240)/400(415)V AC, max.60V DC
Rated current (In): 0.5-63A
Rated frequency (Fn):50Hz
Rated breaking capacity:10KA
Energy limiting class:3
Tripping characteristic: B,C,D
Cross-section of connecting lead:1-25mm²
Isolating class: B
Mounting on the rail:EN50022
Build-in width:18mm/pole
Standard: IEC60898, EN60898 China | | | | | | | Type Tongou residual current circuit breaker without over current protection conforms
to the standards of IEC1008, GB16916, BS EN61008 etc. It is used in the circuits
of AC 50~60Hz, single phase 230V (240V), three phases 400V(415V)
Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current:: 0.5ln
Residual current off-time: ≤0.1s
Minimum value of rated making and breaking capacity:1KV
Rated conditional short-circuit current (Inc):
In=25, 40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail
(surge protective function could be selected)
This series of residual circuit breaker is 4 poles.
Type Tongou residual current circuit breaker without over current protection conforms
to the standards of IEC1008, GB16916, BS EN61008 etc. It is used in the circuits
of AC 50~60Hz, single phase 230V (240V), three ph China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail
(With surge protective function) China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2-pole: 230V AC
4pole: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2-pole: 230V AC; 4-pole: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail
(With surge protective function) China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated Residual Operating Current (In):30,100,300,500ma
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity (Im):1KV
Rated conditional short-circuit current (Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current (Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity (Im): 1KV
Rated conditional short-circuit current (Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail
Panel mounting China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2-pole: 230V AC
4-pole: 400V AC
Rated current (In): 25, 40, 63A
Rated residual operating current (In):30, 100, 300, 500mA
Rated residual non-operating current (Ino):0.5ln
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2 poles: 230V AC
4 poles: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.51n
Residual current off-time:≤0.1s
Minimum value of rated making and breaking capacity(Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | Standard: IEC1008, GB16916, BS EN61008
Rated voltage (Un): 2-pole: 230V AC, 4-pole: 400V AC
Rated current (In): 25, 40,63A
Rated residual operating current (In):30,100,300,500mA
Rated residual non-operating current (Ino):0.51n
Residual current off-time:&le0.1s
Minimum value of rated making and breaking capacity (Im):1KV
Rated conditional short-circuit current(Inc):
In=25,40A Inc=1500A
In=63A Inc=3000A
Installation: on symmetrical DIN rail China | | | | | | | | | | | Miniature Circuit Breaker:
---It is used in the circuit of 50/60Hz,Rated voltage 230/400V.Rated current up to
100A as protection against overload and short circuit.
---It is also as Protection against frequent switchover.
Compliance with standards GB and IEC.
---Rated Voltage: 240V/415V
----Rated Current: 2, 4, 6, 10, 16, 25, 32A
----Breaking Capacity: 4500A
----Mechanical and Electrical Life: 6000 times
----Width Pole: P*N=18mm
Other electronics can be sold:
---Relay or Thermal relay;
---Contactor;
---Motor protector;
---Magnetic Starter;
The detailed outline and mounting dimensions, main technical data related above all
products can be supplied when client enquire it. China | | | | | The product is applicable to a line of AC 50Hz/60Hz, rated voltage 230/400V and rated current up to 63A, used for overload and short circuit protection. It can also be used for infrequent line conversion under the normal condition. Conform the standard: IEC 60947.2 SABS
Type of instantaneous release:
B (3ln~5ln), C(5ln~10ln), D(10ln~14ln)
Poles: 1P, 2P, 3P, 4P
Rated short circuit make and break current: 6KA--10KA
Conform the standard: IEC 60947.2 SABS China | |