| | | Product Description
Standard Configuration
Imported NSK Four-hole high speed handpiece ------------------------ 2 sets
Handpiece with air blow function ---------------------- 1 set
Movable luxury toughened glass cuspidor ---------------------1 set
Constant temperature ration water auto control system for mouth washing and cuspidor flushing ------ 1 set
Electrical dental unit control system (with 3 programmed seating positions)
DC .24V noiseless electrical dental chair ----------- 1 set
Wide backrest and seat
Luxury adjustable headrest -------------------- 1 set
Luminance Adjustable operation light --------- 1 set
AC.220V image viewer ---------------- 1 set
Strong and weak suction handpiece ------------ 1 set
Clean water container ---------------- 1 set
Delivery tray with air brake -------------- 1 set
3 way syringe (cool/warm) ------------ 2 pcs
All functional foot control ------------- 1 set
338C Dentist stool ---------------------- 1 set
Technical Descri China | |
| | | Product Description
Standard Configuration
Four-hole high speed handpiece ------------------------ 1 sets
Movable luxury ceramic cuspidor ---------------------1 set
Constant temperature ration water auto control system for mouth washing and cuspidor flushing ------ 1 set
Electrical dental unit control system
DC .24V noiseless electrical dental chair ----------- 1 set
Luxury adjustable headrest -------------------- 1 set
Luminance Adjustable operation light --------- 1 set
AC.24V image viewer ---------------- 1 set
Strong and weak suction handpiece ------------ 1 set
Clean water container ---------------- 1 set
Delivery tray with air brake -------------- 1 set
3 way syringe (cool/warm) ------------ 2 pcs
Foot control with air blow function ------------- 1 set
Dentist stool ---------------------- 1 set
Technical Description
1.Power for the whole unit----------------------------- 220V / 50Hz
2.Motor power ----------------------------- 24V
3.Water pres China | |
| | | The New Portable LED Teeth Whitening System illuminates the teeth at a wave length of 480 to 520 nanometers, penetrating deep into the teeth and activating the whitening formula to its optimal potency.
In just three 10-minutes cycles, tooth discoloration from years of staining foods, coffee, tobacco, cola, and red wine is eliminated. It also can achieve good effect for the teeth discolored by medicine such as tetracycline or speckled by fluoride.
It adopt the most advantage technology and most comfortable design such as LCD Screen, IC Card Reader. The net weigh of the machine is only 8KG,it’s very convenient to take and easy o operate.
Such design is newest and unique in this line!
China | |
| | | Teeth Whitening System uses high-intensity blue light at a wavelength of 480-520 Nanometers. The light is filtered through over 30 layers of coated optical glass to remove infrared and ultraviolet light. Used together with our special whitening formula, the half hour procedure rapidly oxidizes 16 or more teeth through the dentin tube, restoring them to a beautiful white.
Teeth Whitening operates at a lower temperature than similar products by using the latest optical techniques to avoid irritation of the nerves of the teeth. The 30-minutes process is very effective for teeth that have been stained by smoking or by substance like coffee or tea. It also whitens teeth discolored by medicine such as tetracycline or speckled by fluoride.
Indication: It has good effect for the teeth that have been stained by smoking or stain-causing food and drinks, such as coffee sauce, tea. It also whitens teeth discolored by medicines, such as tetracycline, or speckled by fluoride. Whitens genetic China | |
| | | RAPID MYOGLOBIN TEST CARD
FOR THE QUALITATIVE ASSESSMENT OF HUMAN MYOGLOBIN IN
HUMAN SERUM AND PLASMA
Catalog Number: 75005
For in vitro Diagnostic Use
INTENDED USE
Rapid Myoglobin test is an immunochromatography based one step in vitro test. It is designed for qualitative determination of myoglobin in human serum specimens. The presence of myoglobin in serum or plasma specimens at level 100 ng/ml or higher can be detected in 10 minutes.
SUMMARY AND EXPLANATION
Myoglobin is a low molecular weight, cytoplasmic serum protein. Due to its low molecular weight, myoglobin is released more rapidly when muscle cells are damaged than other markers. Serum concentration of myoglobin increases above the normal range as early as 1 hour after myocardial infarction, and peak in approximately 4 to 8 hours after onset. Therefore, myoglobin is better suited for the early diagnosis of China | |
| | | CK-MB SERUM TEST
FOR THE QUANTITATIVE ASSESSMENT OF HUMAN CK-MB IN
HUMAN SERUM
Catalog Number: 75003
For in vitro Diagnostic Use
INTENDED USE
Rapid CK-MB test is an immunochromatography based one step in vitro test. It is designed for qualitative determination of CK-MB in human serum specimens as an aid in the diagnosis of myocardial infarction.
SUMMARY AND EXPLANATION
Creatine kinase is a dimer occurring in various in three isoenzymic forms, depending on the particular combination of its non-identical subunits:BB(brain type);MM(skeletal type); and MB(hybrid type). Creatine kinase-MB isoenzyme is released into circulation later than myoglubin, reaching abnormal levels within 4 to 6 hours after onset of symptoms,it reaches its highest level with a typical range of 39-185 ng/ml after about 18 to 24 hours,and returns to normal in about 2 to 3 days.CK-MB is w China | |
| | | TROPONIN I TEST CARD
FOR THE QUALITATIVE ASSESSMENT OF CARDIAC TROPONIN I
IN HUMAN SERUM OR PLASMA
Catalog Number: 75001
For in vitro Diagnostic Use
INTENDED USE
Rapid TnI test is an immunochromatography based one step in vitro test. It is designed for qualitative determination of cardiac troponin I (cTnI) in human serum or plasma specimens as an aid in the diagnosis of myocardial infarction.
SUMMARY AND EXPLANATION
Cardiac troponin I (cTnI) is a cardiac muscle protein with a molecular weight of 22.5 kilodaltons. Together with troponin T (TnT) and troponin C (TnC), TnI forms a troponin complex in heart to play a fundamental role in the transmission of intracellular calcium signal actin-myosin interaction. The human cTnI has an additional amino acid residues on its N-terminal that are not exis China | |
| | | Rapid PSA TEST
FOR THE SEMI-QUANTITATIVE ASSESSMENT OF HUMAN PSA IN
HUMAN SERUM AND PLASMA
Catalog Number: 72003
For in vitro Diagnostic Use
INTENDED USE
Rapid PSA Test is an immunochromatography based one step in vitro test. It is designed for the rapid semi-quantitative determination of human prostate specific antigen (PSA) in serum or plasma specimens.
SUMMARY AND EXPLANATION
Prostate cancer is the one of the most common types of cancer found in man. The incidence of prostate cancer increases with age and accounts for a growing number of newly diagnosed patients. Prostate specific antigen (PSA) is produced primarily in the prostate gland and is secreted into the prostate ducts and at ejaculation serves to liquefy the seminal coagulum. Virtually all healthy males under 50 years of age have PSA concentration under 4.0 ng/ml. If PSA level is above 20 ng/ml, the patient most likely to have prostate cancer. Some studies indi China | |
| | | FECAL OCCULT BLOOD TEST CARD
FOR THE QUALITATIVE ASSESSMENT OF HUMAN
HEMOGLOBIN IN FECES
Catalog No.: 07RD-7055
For In-Vitro Diagnostic Use
INTENDED USE
The Fecal Occult Blood test is a qualitative test that detects human hemoglobin in human fecal specimens. The test is a visual one step, in-vitro assay. It is intended for professional use to help diagnose gastrointestinal bleeding.
SUMMARY AND EXPLANATION
Colorectal cancer is the third most common cancer in the world. “Fecal occult blood” is generally defined as a blood loss of less than 50 mL/d. The appearance of occult blood in human fecal specimen is often associated with gastrointestinal diseases which might cause colorectal cancer if not treated promptly and properly. The traditional guaiac-based method lacks sensitivity and specificity, and has diet restrictions prior to the testing.
The Fecal Occult Blood Test uses China | |
| | | RAPID ADENO-ROTA VIRUS ANTIGEN COMBO TEST
Cat.# 71033
Immunochromatographic rapid assay for the Detection of Adenovirus and Rotavirus Antigens in
Human Stool Specimens
INTENDED USE
Rapid Adeno/Rota Combo Test is an in vitro qualitative immunochromatographic assay for the rapid detection of adenovirus rotavirus antigens in human stool specimen. The test results are intended to aid in the diagnosis of rotavirus infection and to monitor the effectiveness of therapeutic treatment.
PRINCIPLE OF THE TEST
Rapid Adeno/Rota Combo Test is a sandwich solid phase immunochromatographic assay. To perform the test, an aliquot of diluted stool sample is added to the sample well of the test cassette. The sample flows through a pad containing antibodies against adenovirus and rotavirus coupled to red-colored colloidal gold. If the sample contains adenovirus or rotavirus antigens, the antigen will bind to the antibody coated on the colloidal gold particles to form antigen-antibody-go China | |
| | | RAPID HELICOBACTER PYLORI ANTIGEN TEST
Cat.# 71020
Immunochromatographic rapid assay for the Detection of Helicobacter pylori Antigens in
Human Stool Specimens
INTENDED USE
Rapid H. pylori Antigen Test is an in vitro qualitative immunochromatographic assay for the rapid detection of Helicobacter pylori antigens in human stool specimen. The test results are intended to aid in the diagnosis of H. pylori infection, to monitor the effectiveness of therapeutic treatment and to confirm the eradication of H. pylori in peptic ulcer patients.
PRINCIPLE OF THE TEST
Rapid H. pylori Antigen Test is a sandwich solid phase immunochromatographic assay. To perform the test, an aliquot of diluted stool sample is added to the sample well of the test cassette. The sample flows through a label pad containing H. pylori antibody coupled to red-colored colloidal gold. If the sample contains H. pylori antigens, the antigen will bind to the antibody coated on the colloidal gold particles t China | |
| | | Datascope Adult finger clip sensor, DB9 male , L=1m
Compatibilities : Datascope Accusat ,Accutorr Plus , passport, Accutorr 3/4 SAT . Direct Connector
. China | |
| | | RAPID H. PYLORI ANTIBODY TEST
Cat.# 71024
A Rapid qualitative Immunochromatographic test for the detection of antibodies against H. Pylori in human Whole Blood, Serum or plasma
INTENDED USE
Rapid H. Pylori Antibody Test is a rapid immunochromatographic assay for the detection of antibodies to H. pylori in human whole blood, serum or plasma. The assay is to provide an aid in diagnosis of H. pylori infection.
TEST PRINCIPLE
Rapid H. Pylori Antibody Test employs chromatographic lateral flow test device in a cassette format. Colloidal gold conjugated H. pylori antigens (Au-Ag) are dry-immobilized at the end of nitrocellulose membrane strip. H. Pylori antigens are bond at the Test Zone (T) When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If anti-H. pylori antibodies present in sample, Antibodies will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Tes China | |
| | | Unique designs to optimize the performance of each application site,to insure patient comfort .
We sell Patient Monitoring cable and leadwires, we have 3-Lead and 5-lead ,AHA and IEC trunk cable and leadwires .Snap and Grabber leadwires. It widely compatible with Philips ,Marquette,Spacelab, Mindray,Nihon Kohden, Welch Allyn,Datex-Ohmeda,S&W artema ,Biosys, MEK ,Colin, Bruker and so on . Welcome to visit our website greatmade.com China | |
| | | It adopts European B standard with 3-times pre-vacuum preceding vacuum drying.Residual humidity is lessthan0.2%; Vacuum measurement reaches-0.8bar.It sterilizes and sanitizes miscellaneous packed or unpacked medical instruments.Whether solid or A-type hollow,wether with multi-opertures or inset pipes.It efficiently tid air from every hollow area of any hollow instrument.such as handpiece,making sure that water steam reaches every comer.
All -round computerized fuzzy control.Digital display modularized ponel for easy operation.
It is installed with BOWIC&DICK which measures the penetration of water steam.
China | |
| | | Rapid Dengue IgG/IgM Combo Test
Cat.# 71019
A Rapid qualitative Immunochromatographic test for the simultaneous detection of IgG and IgM Antibodies to Dengue Virus in human Whole Blood, Serum or plasma
INTENDED USE
Rapid Dengue Test is a rapid immunochromatographic assay for the simultaneous detection of IgG and IgM antibodies to Dengue virus in human whole blood, serum or plasma. The assay is used as a screening test for Dengue viral infection and as an aid for differential diagnosis of primary and secondary infections in conjunction with other criteria.
TEST PRINCIPLE
Rapid Dengue Test utilizes the principle of Immunochromatography. Mouse anti-human IgM and human IgG antibodies are immobilized on the nitrocellulose membrane respectively, as two individual test lines (IgM line and IgG line) in the test window of the test device. The IgG line in the test window is closer to the sample well and followed by IgM line. As the test sample flows through the membrane ass China | |
| | | Class IIB18L
Three times vacuum sterilization cycle progress. It adopts European B standard with 3-times pre-vacuum preceding vacuum drying. Residual humidity is less than 0.2%.
Vacuum measurement reaches-0.8bar. It sterilizes and sanitizes miscellaneous packed or unpacked medical instruments. Whether solid or A-type hollow, wether with multi-opertures or inset pipes. It efficiently tid air from every hollow area of any hollow instrument. Such as handpiece, making sure that water steam reaches every comer.
It is installed with BOWIC&DICK which measures the penetration of water steam.
All -round computerized fuzzy control. LCD creen diaplay modularized ponel for easy operation.
China | |
| | | BD-908
Standard Accessores:
High-Speed Handpiece Pipe (4-holes) X 2 sets
Low-speed Handpiece Pipe(4-holes) X 1 set
Turnable Ceramic Cuspidor(Glass) X 1 set
Automatic Constant Temperature Water System X 1 set
24V Low Voltage X-Film Viewer X 1 set
Water Suction and Saliva Ejector X 1 set each
Inductive Dental Operation light X 1 set
Three Way Syringe X 2 sets
Water Purified Systerm X 1 set
Figure Show The Temperature and Pressure System X 1 set
Dental Stool X 1 set
China | |
| | | BD-904
Standard Accessores:
High-Speed Handpiece(4-holes) X 2 sets
Low-speed Handpiece(4-holes) X 1 set
DC Driven Chair X 1 set
Extendable Cushion and Backrest X 1 set
X-Ray Viewer X 1 set
Auto Spittoon Flush and Cup Filler Control System X 1 set
Clean Water System X 1 set
Three Way Syringe X 2 sets
Saliva Ejector X 1 set
High Suction X 1 set
Dental Light X 1 set
Dental Stool X 1 set
Multifunction Kick Switch X 1 set
China | |
| | | Specifications:
Model: BD-401
Voltage: 110V~240V, 50Hz/60Hz
Power: 220W
Airflow: 100L/min
Noise: 50dB(A)/40"
Pressure: 8 Bar
N. W.: 8.8 Kgs
Dimension: 40CMx23CMx18CM
Descriptions:
* Portable Type, Light In Weight: 8.8Kgs. Compact and Easy to Take
* Silent and Oilless Type, Without maintenance
China | |