| | | Water-resistant
Low Power Consumption
Automatice Switch-off
Low-battery Alarm (as long as there is any display
the accuracy is guaranteed)
Model: ZTS-CF ZTS-EC ZTS-TDS ZTS-uS/cm ZTS-mS/cm ZTS-ppm ZTS-ppt
Measuring Range: 0-100 CF 0-19.99 EC 0 -1999 mg/l 0-1999 uS/cm 0-19.99 mS/cm 0-1999 ppm 0-10.00 ppt
Resolution: 1 CF 0.01 EC 1 mg/l 1 uS/cm 0.01 mS/cm 1 ppm 0.01 ppt
Accuracy:+/-2% FS
Temp: 5 - 50°C (ATC)
Size; 150 x 32 x 16 mm
China | |
| | | Waterproof
-Low Power Consumption
-Automatice Switch-off
-Low-battery Alarm (as long as there is any display
the accuracy is guaranteed)
Model: ZDS-EC ZDS-TDS ZDS-uS/cm ZDS-mS/cm ZDS-ppm ZDS-ppt
Measuring Range: 0-19.99 EC 0-1999 mg/l 0-1999 uS/cm 0-19.99 mS/cm 0-1999 ppm 0-10.00 ppt
Resolution: 0.01 EC 1 mg/l 1 uS/cm 0.01 mS/cm 1 ppm 0.01 ppt
Accuracy +/-2% FS
Temp 5 - 50°C (ATC)
Size 150 x 32 x 20 mm
China | |
| | | Model :PH-890 PH-990
Measuring Range 0.00 - 14.00 pH 0 - ±199.9 mV 0 - ±1999 mV 0~100 °C, 0.00 - 14.00 pH 0 - ±1999 mV
0 - 2x10000 uS/cm 0~100 °C
Resolution :0.01 pH 1 mV 0.1 °C ,0.01 pH1 mV 0.1 °C0.1 1 10 100 uS/cm
Accuracy: +/- 0.01 pH ± 0.1% FS ±1% FS , ± 0.01 pH
± 0.1% FS ±1% FS ± 0.5 °C
Calibration: 2 points (4.01 pH, 6.86 pH or 9.18 pH)
Temp: 0 - 100 °C (ATC)
China | |
| | |
(0.01 pH resolution)
- Water-resistant
- Low Power Consumption
- Automatice Switch-off
- Low-battery Alarm
(as long as there is any display, the accuracy is guaranteed)
Model: PH-903 PH-903A
Measuring Range: 0.00 - 14.00 pH
Accuracy: Calibration: 2 points
Plug: fixed electrode
Temp: 5 - 50°C (ATC)
Size: 150 x 22 x 16 mm
China | |
| | | (0.01 pH resolution)
Totally Waterproof
Low Power Consumption
Automatice Switch-off
Low-battery Alarm
(as long as there is any display, the accuracy is
guaranteed)
Model :PH-901 PH-901A PH-901B PH-902A PH-902A
Measuring Range: 0.00 - 14.00 pH
Calibration: 2 points
Plug: fixed electrode fixed electrode BNC + 1 m cable replaceable electrode replaceable electrode
Temp: 5 - 50A°C (ATC)
Size: 150 x 22 x 20mm
China | |
| | | For lab application, especially useful for solution that is corrosive to PC plastic and circumstances where higher temperature is consecutiely measured. Normally used with reductive media.
Model 99Pt-A 99Pt-B
Measuring Range +/- 1500 mV
Junction Ceramic
Reference Cell Ag/Agcl, KCL gel
Sensitive Component dia.1 x 6mm Platinum needle dia.6 x 2.5mm Platinum ring
Size dia.12 x length 160 mm
Plug BNC + 1 m cable
Note: Difference between the two models is the shape of the sensitive component. A is needle and B is ring.
China | |
| | | Note:
84-IP can be generally used in lab. 84-IIP is the accessory electrode for pH meter model P-IA and PX-IA. It has a special direct BNC plug to be connected to pH meter.
These three models are acceossories for Pocket pH meter PH serie.
87-IP is for PH-I. It has a special direct plug for connection. It is smaller in size so that it can be temperarily stored in the body of PH-I
87-IIP is for PH-II, can also be generally used in lab.
87-IIIP is for PH-III, can also be generally used in lab.
Model : 84-IP 84-IIP 87-IP 87-IIP 87-IIIP
Measuring Range: 0 - 14 pH
Temperature Range: 0 - 60°C
Zero point value: 7 +/- 1 pH
Junction: Ceramic
Reference: Cell Ag/Agcl, KCL gel
Size: dia.10 x length 120 mm ,dia.10 x length 120 mm, dia.12 x length 85 mm ,dia.12 x length120 mm ,dia.12 x length 90mm
Plug : BNC + 1 m cable, BNC ,Special direct plug ,BNC ,BNC + 1 m cable
China | |
| | | Note: Difference between the two models is the reference cell electrolyte. 65-IP is with solution form and can be refilled. 65-IIP is in gel form which last life time, not need to refill.
Difference between the two models is the shanpe of the tip. 65-IA is sharper, 65-IIA is a little round
Model ; 65-IP 65-IIP 65-IA 65-IIA
Measuring Range: 0 - 14 pH
Temperature Range: 0 - 60°C
Zero point value: 7 +/- 1 pH
Junction: Ceramic
Reference Cell: Ag/Agcl, KCL solution refillable Ag/Agcl, KCL gel Ag/Agcl, KCL solution refillable
Size: dia.12 x length 140 mm dia.9 x length 140 mm
Plug: BNC + 1 m cable
China | |
| | | Model 2D-SY (6.3-80 Mpa) electric hydraulic test pump is the up-to-date series product designed by the Joint Design Group for Hydraulic Test Pump of the General Machinery Research Institute under the Ministry of Machine-Building Industry. It features high level of ” Mechanization, Electrification and Automation”, long service life, stable performance, flexibility and lightweight that the old products enjoy. What’s more, a drive unit and cross-like converter are added so that the comprehensive indicators of the series product can meet the requirement, various performances become more stable and reliable with safe and easy use and power conservation. In its structure, an enclosed water tank is used, thereby reducing the height of the whole unit and making it more compact and attractive. China | |
| | | Winner99 is this instrument specially used for anglyzing particle size and shape. It gains the particle information through elaborately designed optical microscope and professional lens of camera.It tests particle size, distribution and paricle shape characteristics by adopting the technology of image analusis with computer. The instrument has outstanding characteristics including easy operation, clear image,intuitional test, high resolution (high as 0.1um/picture element)and extensive application,etc. It can be used in colleges, universities, research institutes and large and midium-sized enterprises for new products developing, guality and technology controlling. China | |
| | | Except sample injection, tester only need to operate the computer .The smartest and intelligent instrument in China, only through computer operation, you can complete the whole process which is much convenient and time-effective. China | |
| | | WF30-15 Cone-shaped Flow meter Pipe type (Straight welding)
1. Specification: Cone-shaped flow meter is a new-style of high accuracy flow meter which can measure various of medium. A cone is positioned in the center of the pipe to block the liquid and create a differential pressure between upstream & downstream, this pressure difference can be corresponding to medium flowrate. Two pressure port are provided on two side of flow meter as high pressure port and low pressure port.
1. Apply to: Air, liquid & steam in pipe.
2. Pipe diameter: 15mm~2000mm or more.
3. Pressure grade: PN0.25-42.0
4. Accuracy:±0.5% of measure value
5. Turndown: 10:1 or more
6. Repeatability:±0.1%
7. Standard Betas: 0.450-0.850
8. Pressure loss: % of differential pressure, varies with beta ratio.
9. Installation: 0-3D upstream, 0-1D downstream.
China | |
| | | WF30-14 Cone-shaped Flow meter Wafer type
Specification: Cone-shaped flow meter is a new-style of high accuracy flow meter which can measure various of medium. A cone is positioned in the center of the pipe to block the liquid and create a differential pressure between upstream & downstream, this pressure difference can be corresponding to medium flowrate. Two pressure port are provided on two side of flow meter as high pressure port and low pressure port.
1. Apply to: Air, liquid & steam in small diameter, high flowrate pipe.
2. Pipe diameter: 15mm~150mm.
3. Pressure grade: PN0.25-25.0
4. Accuracy:±0.5% of measured value
5. Turndown: more than 10:1
6. Repeatability:±0.1%
7. Standard Betas: 0.450-0.850
8. Pressure loss: % of differential pressure, varies with beta ratio.
9. Installation: 0-3D upstream, 0-1D downstream.
China | |
| | | WF30-13 Cone-shaped Flow meter Plug type
Specification: Cone-shaped flow meter is a new-style of high accuracy flow meter
which can measure various of medium. A cone is positioned in the center of the pipe to block the liquid and create a differential pressure between upstream &
downstream, this pressure difference can be corresponding to medium flowrate.
Two pressure port are provided on two side of flow meter as positive pressure port
and negative pressure port.
1. Apply to: Air, liquid & steam in pipe.
2. Pipe diameter: 15mm~2000mm or more.
3. Pressure grade: PN0.6-2.5
4. Accuracy: ±0.5% of measure value
5. Turndown: 10:1 or more
6. Repeatability: ±0.1%
7. Standard Betas: 0.450-0.850
8. Pressure loss: % of differential pressure, varies with beta ratio.
9. Installation: 0-3D upstream, 0-1D downstream.
China | |
| | | WF30-12 Cone-shaped Flow meter Pipe type (Flange with neck)
Specification: Weiriy cone-shaped flow meter is a new-style high precision flow sensor who can measure all kinds of media. The cone piece throttle hanging over the pipeline center can baffle the fluid, which forms into differential pressure at the up and downriver of the cone. The ?P corresponds with the media flux, and there are two pressure ports located at the forth and after of the flow sensor respectively positive pressure port and negative pressure port.
1. Apply to: Air, liquid & steam in pipe.
2. Pipe diameter: 15mm~2000mm or more.
3. Pressure grade: PN0.25-42.0
4. Accuracy: ±0.5% of measure value
5. Turndown: more than 10:1
6. Repeatability: ±0.1%
7. Standard Betas: 0.450-0.850
8. Pressure loss: % of differential pressure, varies with beta ratio.
9. Installation: 0-3D upstream, 0-1D downstream.
China | |
| | | WF30-11 Cone-shaped Flow meter Pipe type (Flat Flange)
Specification: Cone-shaped flow meter is a new-style of high accuracy flow meter which can measure various of medium. A cone is positioned in the center of the pipe to block the liquid and create a differential pressure between upstream & downstream, this pressure difference can be corresponding to medium flowrate. Two pressure port are provided on two side of flow meter as high pressure port and low pressure port.
1. Apply to: Air, liquid & steam in pipe.
2. Pipe diameter: 15mm~2000mm or more.
3. Pressure grade: PN0.25~42.
4.Accuracy: ±0.5% of measure value
5.Turndown: more than 10:1
6. Repeatability: ±0.1%
7. Standard Betas: 0.450-0.850
8. Pressure loss: % of differential pressure, varies with beta ratio.
9. Installation: 0-3D upstream, 0-1D downstream.
China | |
| | | MDOEL Z3032X7 Z3032X9
Max.Drilling Capacity 32mm 32mm
Max. Tapping Ca[acity 20/16 18/14
Distance of spindle
axis to colomn surface 300~700mm 260~900mm
distance of spindle
nose to table surface 275~680mm 220~1100mm
spindle taper MT3 MT4
soindle travel 150mm 120mm
spindle speed and number 100~1600/8s 108~1000/4s
table size 250x250mm 430x300mm
rotary angle of rocker
in horizontal plane 360 360
spindle feeding 0.08,0.14,0.23mm/r
main motor power 750/1100w 850/1100w
China | |
| | | You can also write to jason_machinery@hotmail.com or call 008613964252961 to get more .
NC 654Performance Specifications
Measuring Strokes : 600(mm) x 500(mm) x 400(mm)
Overall Dimension : 1630(mm) x 1280(mm) x 2380 (mm)
Max part weight : 500 kg
Resolution : 0.1 (mm)
Accuracy according GB/T16857.2-1997 equal ISO 10 360:
(Volumetric length measuring error) E =2.5 +3.5L/1000 [mm](Volumetric Probing Error) R = 2.4 mm
Environment Specifications
Room required specifications
Average room temperature: 18 - 22 °C
Maximum thermal gradients:1 °C/h,2 °C/day,1 °C/m,
Air supply system
(Min. air pressure) : 0.7 MPa
Electrical requirements
- (Voltage) : 220 Vac ± 10%
(Frequency) : 50 Hz
(Current) : 10 A
Allowed Maximum Floor Vibration (Frequency Range): 0 ~ 19 Hz China | |
| | | NC 654Performance Specifications
Measuring Strokes : 600(mm) x 500(mm) x 400(mm)
Overall Dimension : 1630(mm) x 1280(mm) x 2380 (mm)
Max part weight : 500 kg
Resolution : 0.1 (mm)
Accuracy according GB/T16857.2-1997 equal ISO 10 360:
(Volumetric length measuring error) E =2.5 +3.5L/1000 [mm](Volumetric Probing Error) R = 2.4 mm
Environment Specifications
Room required specifications
Average room temperature: 18 - 22 °C
Maximum thermal gradients:1 °C/h,2 °C/day,1 °C/m,
Air supply system
(Min. air pressure) : 0.7 MPa
Electrical requirements
- (Voltage) : 220 Vac ± 10%
(Frequency) : 50 Hz
(Current) : 10 A
Allowed Maximum Floor Vibration (Frequency Range): 0 ~ 19 Hz 19~75 Hz > 75 Hz
NC series is the latest generation of Movi China | |
| | | NCF 1087 Performance Specifications
Measuring Strokes :1000(mm) x 800(mm) x 700(mm)
Overall Dimension : 2550(mm) x 1700(mm) x 3200 (mm)
Max part weight : 700 kg
Resolution : 0.1 (mm)
Accuracy according GB/T16857.2-1997 equal ISO 10 360:
Volumetric length measuring error E =1.6 +L/300 [mm]
Volumetric Probing Error R =2.0mm
Environment Specifications
Room required specifications
- Average room temperature: 19 - 21 °C
- Maximum thermal gradients:0.5 °C/hour,1 °C/day,0.5 °C/m,
- Air supply system
- Min. air pressure : 0.7 MPa
- Min. air consumption : 0.1 m3/min
Electrical requirements
- Voltage : 220 Vac ± 10%
- Frequency : 50 Hz
- Current : 10 A
Allowed Maximum Floor Vibration
- Frequency Range: 0 ~ 19 Hz 19~75 Hz > 75 Hz
-Maximum Amplitude: 0.0011 mm 0.0011~0.002 mm 0.002 mm
China | |
Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 show 301 ~ 296 of 296 Total 15 pages |