Advertisements
Contact Us
Chanko Electric Stock Co., Ltd.
[China]
Street Address : Liushi Chanhe Industrial Zone, Yueqing,Zhejiang
ZipCode : 325604
Phone : 86-577-61726105, 13695712969
Circuit breakers,contactors, thermal relays & starters, fuses, switches, push buttons, instruments & meters, distribution boxes and electrical accessories
home
Product list
Advertisements
Product List
1.CX-AM01 electric bladeless fan/Air multiplier 2.Various colors for products 3.Safe fan no leaf 4.Easy clean
[Related Categories:Home Appliances >> Air Conditioner]
[Relative Keyword: Air multiplier, torque multiplier, port multiplier, power multiplier ]
[Relative Keyword: Air multiplier, torque multiplier, port multiplier, power multiplier ]
1.CJX2-E06 LC1-E06 AC Contactor 2.Various Quality Levels for Selection 3.Certificate: CE/ISO9001/ROHS 4.OEM
[Related Categories:Electronics & Electrical >> Contactor]
[Relative Keyword: magnetic contactor, siemens contactor, ac contactor ]
[Relative Keyword: magnetic contactor, siemens contactor, ac contactor ]
signal indicator(indicator light)1.Application: XB2 series of push button are used in control circuit of AC50Hz or 60Hz, voltage up to 660V, DC voltage up to 400V and below, its used for controlling signal and interlocking. The main body adopts zinc alloy or high grade anti-flaming plastic, the contacts adopt special silver alloy, so it has strong anti-electrical erosion property, the signal lamps series are suitable for electrical appliances circuit of AC voltage 380V, 50Hz or 60Hz, DC voltage up to 380V and below, its used as kinds of lights indication signal, warning signal, accident signal and others.2. Working Environment:A). Environment Temperature: -25 to +55;B). Air relative humidity: ≤85%;C). It can work normally when the vibration frequency is 2-80Hz, the acceleration is 0.7g;D). Pollution grade is 3, installation sort is III, protection grade is above IP65;E). Altitude: ≤2000m3. Main Technical DataPush ButtonSignal LampRated Insulation VoltageAC 600V (50Hz/60Hz)Insulat
[Related Categories:Security & Protection >> Alarm]
[Relative Keyword: signal indicator, signal indicator(indicator light) ]
[Relative Keyword: signal indicator, signal indicator(indicator light) ]
Application: 3RU series thermal relay are suitable for using in the power system with AC5050/60Hz rated operation voltage up to 690-1000V, rated operation current from 0.1A to 100A, they are used to protect AC 3 phase asynchronous motors against overload and phase failure, they also have the functions of temperature compensation and trip indication. The products can be fixed with 3RT series contactors, or be independently fixed, conform to IEC60947-4-1.Specification:TypeMotor Power (kW)Current Range (A)ContactorTypeMotor Power (kW)Current Range (A)Contactor3RU-120.040.11-0.163RT-10153RT-10163RT-10173RU-2535.5-83RT-10253RT-10260.060.14-0.247-100.060.18-0.255.59-12.50.090.22-0.327.511-160.090.28-47.514-200.120.35-0.51117-220.180.45-0.631120-250.180.55-83RU-5035.5-83RT-10343RT-10353RT-10360.250.7-147-100.370.9-1.255.59-12.50.551-1.67.511-160.751.4-27.514-200.751.8-2.51118-251.12.2-3.21522-321.52.8-418.528-401.53.5-52236-452.24.5-6.32240-5035.5-83RU-1001118-253RT-10443RT-10453RT-104647-101
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: thermal relay ]
[Relative Keyword: thermal relay ]
Application: XB2 series pushbutton switches are used in industrial controlling circuits of AC 50Hz or 60Hz, rated operational voltage up to 380V and below, DC operational voltage up to 220V and below for controlling in magnetic starter, contactor, relay and other electrical circuits. The buttons with indication conform with the standard of GB14048.5-2001.Main Technical ParameterAmbient Temperature:-5+40Relative Humidity:45%85%Contact Resistance:≤50mΩElectrical Life5.0x105Withstanding Voltage2500V, 1minProtection DegreeIP40Rated Insulation Voltage, Ui660VConventional Thermal Current, Ith10ARated Operational Voltage, Ue380V220V110V48V24VRated Operational Current, IeAC-152.5A4.5A6A8A-DC-13-0.3A0.6A1.3A2.5ARated VoltageVoltage Input DirectlyResistanceTransformerLamp-House6V12V24V48V110V220V380V220V220V380VLED Lamp√√√-----√√Neon Lamp----√√√√--Incandecent Lamp√√√√√√√-√√
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: pushbutton switch ]
[Relative Keyword: pushbutton switch ]
6. cable tie
Material: Nylon 66, 94V-2 certificated by UL. Heat-resisting, erosion control, good insulation and not apt to age.Color: Natual (or white, standard color), UB black and other colors are avaialbe as requested.Technical Data:SpecificationLengthWidth (mm)Bundle Range (mm)Tensile StrengthInchMMLBSKgs4.8x1204.71204.83-3050223.8x1606.31603-404.8x1807.11803-424.8x1907.51903-464.8x2008.02003-504.8x25010.02503-654.8x28011.02803-704.8x30012.03003-804.8x35014.03503-904.8x36014.23603-944.8x37014.63703-984.8x38015.03803-1024.8x40016.04003-1054.8x43016.94303-1204.8x45017.74503-1304.8x50019.75003-150
7. cable tie
Material: Nylon 66, 94V-2 certificated by UL. Heat-resisting, erosion control, good insulation and not apt to age.Color: Natual (or white, standard color), UV black and other colors are avaialbe as requested.Technical Data:SpecificationLengthWidth (mm)Bundle Range (mm)Tensile StrengthInchMMLBSKgs7.2x1506.01507.23-35120557.2x2008.02003-507.2x25010.02504-657.2x28011.02804-787.2x30012.03004-807.2x35014.03504-907.2x37014.63704-987.2x38015.03804-1007.2x40016.04004-1057.2x45018.04504-1107.2x50020.05004-1507.2x53020.95304-1607.2x55021.65504-16512x65025.665012.014-18525011412x90025.590014-265
8. cable tie
Material: Nylon 66, 94V-2 certificated by UL. Heat-resisting, erosion control, good insulation and not apt to age.Color: Natual (or white, standard color), UB black and other colors are avaialbe as requested.Technical Data:SpecificationLengthWidth (mm)Bundle Range (mm)Tensile StrengthInchMMLBSKgs2.5x602.4602.52-111682.5x803.2802-162.5x1004.01002-222.5x1204.71202-302.5x1506.01502-352.5x1606.31602-402.5x2008.02003-503.6x1405.51403.63-334018.003.6x1506.01503-353.6x1807.11803-423.6x2008.02003-503.6x250102503-653.6x280112803-703.6x300123003-803.6x37014.63703-105
see attached file of lte1102.
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: warning light, lte1102 ]
[Relative Keyword: warning light, lte1102 ]
10. Inverter
Application: Such inverter of 300W can invert power source with DC48V into power with output of AC220V or 110V.Technical Data:Type8807-1128807-1248807-1488807-2128807-2248807-248Input Voltage (DV)10.5-1521-3042-6010.5-1521-3042-60Output Voltage (AC)100/110/115/120±3%200/220/230/240±3%Actual Power500WInstantanious Power1000WEfficiency when full-load87%90%92%90%93%94%Current without load0.4A0.23A0.23A0.4A0.23A0.2AOutput WaveSine Wave (Modified, 0.2%Output Voltage100/110/115/120V±4%200/220/230/240±4%Fault IndicationLED turns redOuter Dimension167(L)mmx92(Wmmx49(H)mmWeight1kg
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: inverter ]
[Relative Keyword: inverter ]
11. relay socket
We can also supply kinds of sockets for mini relays, such as PYF-08A, PYF08A-E, PYF11A, PYF14A etc with good quality and competitive prices.
[Related Categories:Electronics & Electrical >> Electrical Plugs & Sockets ]
[Relative Keyword: relay socket, socket ]
[Relative Keyword: relay socket, socket ]
Technical DataTypeMK2P-IMK2PN-IMK3P-IMK3PN-ITerminal Layout2Z2Z3Z3ZSize (mm)34.7x34.7x52Contact CapacityAC220V 10A, DC28V 10AContact Resistance (mΩ)≤50 mΩInsulation Resistance (mΩ)≥500 mΩDielectric StrengthBOC 1500VACBCC 1500VACCoil Nominal VoltageAC:6-380V, DC6-220VCoil Nominal PowerAC:≤0.8VA, DC:≤1.6VAOperating Temerpature ()-40 to +60Weight (g)≤80Mounting Methodsoutlet
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: mini relay, general purpose relay ]
[Relative Keyword: mini relay, general purpose relay ]
13. time relay
Techncial DataDimension (mm)48x48x97Working MethodsPower Supply DelayDelaying Range0.01-99.9s0.01m-99.99m0.01-99.99hRated VoltageDC(V): 12,24,48,110AC(V): 12,24,48,110,220,380, 50/60HzContact Point Quantity2 Groups of Delaying Contact PointsContact Point CapacityAC250V, 5A, ResistanceDelaying Accuracy0LifeMechanical5x105Electrical105Installation MethodsPanel
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: time relay, dh48s ]
[Relative Keyword: time relay, dh48s ]
Features: A large and bright meter with a scale length of 80mm, and its sensitivity of 44mA at full scale; Excellent 2mV DC resolution factor and expanded resistance measurement from 0.2 to 20kA; Fuse Protection.Specifications:Voltage DC: 0.1/0.5/2.5/10/50/250/1000VVoltage AC: 10/50/250/1000VCurrent DC: 50uA/2.5mA/25mA/0.25AResistance: Rx1/Rx10/Rx1k/Rx10kΩPower: 9V(6F22)/1.5V(AA)x2Dimension(WxLxT): 100x148x35mmWeight: 280g, with battery
[Related Categories:Measurement & Analysis Instruments >> Electrical Instruments ]
[Relative Keyword: digital multimeter, yx360trn ]
[Relative Keyword: digital multimeter, yx360trn ]
Type: 261 SeriesRated Voltage: 500VDCResistance: 20MΩ/2000MΩDimension(WxLxT): 70x90x35mmWeight: 130g (with battery)
[Related Categories:Measurement & Analysis Instruments >> Testing Equipment]
[Relative Keyword: insulation tester, dt261 ]
[Relative Keyword: insulation tester, dt261 ]
Application: The DTS(X)577 DSS(X)577 type meter assume high accurately a nd high reliable. Adopting advanced super-low power consumption LSI a nd SMT technology of international.Selecting international quality brand a nd long life component, improved the reliable a nd service life of the products. It can measure active a nd reactive energy accurately for three-phase rated frequency 50Hz, it can replace of two common three-phase meters. Reading visual a nd use convenient the performance is in conformity with the technical requirements for three-phase watt-hour meter stipulated in GB/T17215-2002 Class 1 a nd 2 Static A.C Active Watt-hour MeterGB/T17882-1999 Class 2 a nd 3 Static A.C Reactive Watt-hour Meter standard.Function and Features:1. Two-way power measure a nd electricity stealing proof, high accuracy, high reliability, high overload, low power consumption, light weight etc. 2. Measure three-phase active electric en
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: kilo watt hour meter, dt(x)577 ]
[Relative Keyword: kilo watt hour meter, dt(x)577 ]
Application: DD28 single-phase watt-hour meter is a kind of induction meter, which is applicable to measure the rated frequency 50Hz a nd power loss in electrified wire netting. All technical targets are completely conformed to National Standard GB/T15283-94 a nd International Standard IEC60521.Structure and features: The meter has separable electromagnet three kinds: single-jewel, dual jewel, magnetic thrust a nd magnetic floating. The case has three kinds; aluminum, plastic a nd glass. The die-casting frame is alloy aluminum with excellent mechanical strength.Technical Data:TypeAccuracyRated Voltage (V)Rated Current (A)Overload CapacityStarting CurrentInsulation PerformanceDD282Class 2220V2(4)A, 2.5(5)A, 3(6)A, 5(10)A, 10(20)A, 20(40)A, 30(60)A, 40(80)A200%Ib0.5%IbAC Voltage 2kV for 1 minute impulse voltage 6kVDD2832(6)A, 3(9)A, 5(25)A, 10(30)A, 15(45)A, 20(60)A300%Ib0.5%IbDD2845(20)A, 3(12)A, 10(40)A, 15(60)A, 20(80)A400%Ib0.5Ib
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: kilo watt hour meter, dd282 ]
[Relative Keyword: kilo watt hour meter, dd282 ]
18. fuse
Application: The series of fuse links are mainly used in AC50Hz, rated voltage up to 690V, rated current up to 1250A and for protecting electrical equipment from overloading and short-circuit. It can reliably break the min fuion current to current within 120kA. Its also avaible for the protection of semiconductor parts and equipments against short circuit and motors.Technical Data:Fuse Link TypeRated Voltage (V)Rated Current (A)Weight (g)Outer Dimension (mm)ABCDHNT00C, NH00C500/6904-10015078.549152152.5NH00C500/6904-1001237849152148NH00C500/6904-1001177849152148NH00C, 3NA3500/69010-1601327849152152.5NT00, NH00500/6904-1601507849152956.53NA500/6904-160176.57849152859NH0050010-160178.57839153053NT0, NH0500/6904-16020012568152956.53NE500/11404-16027812568152961.5
SC(JGY) copper connecting terminalThese products are applicable for the connection of copper products (section area 1.5-100mm2) in power cable with electrical equipment, they are made of more than 99.99% pure copper tube T2 and coated with tin, working temperature -55 to +150.Outer dimension and drawing:TypeφDdLSC(JGY)-1.5φ4.2, φ5.23.51.818SC(JGY)-2.5φ4.2, φ5.2, φ6.242.519SC(JGY)-4.0φ5.2, φ6.24.83.121SC(JGY)-6.0φ5.2, φ6.2, φ8.25.53.824SC(JGY)-10φ6.2, φ8.26.84.825.5SC(JGY)-16φ6.2, φ8.2, φ10.57.55.530.5SC(JGY)-25φ6.2, φ8.2, φ10.59734SC(JGY)-35φ6.2, φ8.2, φ10.5, φ12.510.58.238SC(JGY)-50φ8.2, φ10.5, φ12.512.59.845SC(JGY)-70φ8.2, φ10.5, φ12.514.511.550SC(JGY)-95φ10.5, φ12.517.513.855.5SC(JGY)-125φ12.5, φ16.519.515.563SC(JGY)-150φ12.5, φ16.52116.571SC(JGY)-185φ16.523.518.878SC(JGY)-240φ16.526.52192SC(JGY)-300φ16.5, φ20.53024102SC(JGY)-400
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: connecting terminal, sc(jgy) ]
[Relative Keyword: connecting terminal, sc(jgy) ]
20. connecting tube
GTY copper connecting terminalThese products are applicable for the connection of the circuilar wire, hemicycle wire with power supply cable in distribution equipment, they are made of higher than 99.9% pure T2 copper tube, and coated with tin.Outer dimension and drawing:TypeDdLGTY-1.53.71.820GTY-2.542.520GTY-4.04.83.120GTY-5.55.53.825GTY-106.84.830GTY-167.55.535GTY-259740GTY-3510.58.245GTY-5012.59.850GTY-7014.511.555GTY-9517.513.560GTY-12019.51565GTY-1502116.570GTY-18523.518.575GTY-24026.52180GTY-300302485GTY-400342790GTY-5003830100GTY-6304535110GTY-8005039150GTY-10005644170
[Related Categories:Security & Protection >> Police and Military Supplies]
[Relative Keyword: connecting tube ]
[Relative Keyword: connecting tube ]