Specifications:
1) Output range: from 24kW (30kVA) up to 120kW (150kVA)
2) Engine model: D226B-3D, TD226B-3D, TD226B-4D, TBD226B-6D5, TD226B-6D
3) Alternator model: GM/MP/UC
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat; The water
is over temperature; The oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration:
1) Engine model: TD226B-6D
2) Alternator model: UCI274E
3) Rated output: 75kW (93.75kVA)
4) Closed cooling
5) Fuel consumption: 220g/kWh
6) Prepare output: 84kW (105kVA)
7) Rated voltage: 230 / 400V
8)
Specifications:
1) Output range: from 75kW (93.75kVA) up to 400kW (500kVA)
2) Engine model: TD520GE, TD720GE, TAD740GE, TWD710G, TAD1240GE,
TAD1242GE, TAD1630GE
3) Alternator model: GM/MP/UC
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: TAD740GE
2) Alternator model: UCD274K
3) Rated output: 200kW (250kVA)
4) Closed cooling
5) Fuel consumption: 210g/kWh
6) Prepare output: 220kW (105kVA)
Specifications:
1) Output range: from 30kW (37.5kVA) up to 150kW (187.5kVA)
2) Engine model: R3105D1, R4100D1, R4100ZD1, R4105D1, R4105ZD1, R6105ZD1, R6105ZLD
3) Alternator model: GM/MP/TFS
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration:
1) Engine model: R6105IZLD
2) Alternator model: CR-120
3) Rated output: 120kW (150kVA)
4) Closed cooling
5) Fuel consumption: 210g/kWh
6) Prepare output: 145kW (181.25kVA)
7) Rated volta
Specifications:
1) Output range: from 100kW (125kVA) up to 400kW (500kVA)
2) Engine model: X6135JD-1, X6140AD, X6135JZD-1, X6135JZLM, X61354JZLD,
WX6135ZLD, WJ6135ZLD, WD315TAD28
3) Alternator model: GM/MP
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: X6135JZD-1
2) Alternator model: TZH-150
3) Rated output: 150kW (187.5kVA)
4) Closed water cool
5) Fuel consumption: 210g/kWh
6) Prepare o
Specifications:
1) Output range: from 15kW (18.75kVA) up to 30kW (37.5kVA)
2) Engine model: 195D, 295D, 495D, K4100D
3) Alternator model: GM/CR
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: 195D
2) Alternator model: GM
3) Rated output: 30kW (37.5kVA)
4) Closed cooling
5) Fuel consumption: 235g/kWh
6) Prepare output: 33kW (41.25kVA)
7) Rated voltage: 230 / 400V
8) Rated current: 54.1A
9) Po
The sound-proof type genset has perfect all-weather service property and the outside steel material features preferable corrosion prevention capability. Special noise elimination setting restrains machinery noise to be lowered below 75dB.
Specifications:
1) Output range: from 10kW (12.5kVA) up to 1,000kW (1250kVA)
2) Engine model: 2100 series, R series, D226B series, WD615 series, TAD-TWD series
3) Alternator model: GM/MP/UC
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alar
Specifications:
1) Output range: from 10kW (12.5kVA) up to 1,000kW (1,250kVA)
2) Engine model: 2100 series, R series, D226B series, WD615 series, KTA series
3) Alternator model: GM/MP/UC
4) Water-cooled
5) Key start / auto start, low noise (75-80db)
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: R4105ZD
2) Alternator model: MP-50
3) Rated output: 50kW (62.5kVA)
4) Closed cooling
5) Fuel consumption: 220g/kWh
6) Prepare output: 56kW (70kVA)
7) R
Specifications:
1) Output range: from 8kW (10kVA) up to 15kW (18.5kVA)
2) Engine model: 195D, 1100D, 1110D, 1105D, 1115D, 1125D
3) Alternator model: CR/TFS
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: 1110D
2) Alternator model: CR-10
3) Rated output: 10kW (18.5kVA)
4) Closed cooling
5) Fuel consumption: 235g/kWh
6) Prepare output: 12kW (15kVA)
7) Rated voltage: 230 / 400V
8) Rated current:
Specifications:
1) Output range: from 300kW (375kVA) up to 500kW (625kVA)
2) Engine model: X6170Z, X6170ZD-3A, X6170Z-2
3) Alternator model: GM / MP
4) Water-cooled
5) Fuel consumption: <195g/kWh
6) Low noise
7) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four-wire
alternating current output
8) Key start / auto start
9) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
10) Rotate speed: 1,500rpm
11) Filter system: oil, fuel and air filter
12) Accessories: exhaust elbow, bellow, muffl
Specifications:
1) Output range: from 200kW (250kVA) up to 800kW (1,000kVA)
2) Engine model: NTA855-G1
3) Alternator model: GM/MP/UC
4) Water-cooled
5) Key start / auto start, low noise
6) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
Standard configuration of gensets:
1) Engine model: NTA855-G1
2) Alternator model: MP-200
3) Rated output: 200kW (250kVA)
4) Closed cooling
5) Fuel consumption: 210g/kWh
6) Prepare output: 220kW (275kVA)
7) Rated voltage: 230 / 400V
8) Rated current: 361A
9) Power