| | | [2008-10-14] Used for intracellular signal measuring system0.5 mm and/or 1 mm per scale divisionadjustable in 3 perpendicular planes (x, y, z) Electronics & Electrical >> Others | |
| | | [2008-10-14] Used for intracellular signal measuring system0.5 mm and/or 1 mm per scale divisionadjustable in 3 perpendicular planes (x, y, z) Electronics & Electrical >> Sensors | |
| | | [2008-10-14] used for TSZ-02 / TSZ-04 tissue bath systems0.5 mm or 1 mm per scale divisionadjustable in 1 perpendicular plane (x) Electronics & Electrical >> Others | |
| | | [2008-10-14] Working temperature range: +20 °C... +40 °CTemperature stability: ±0.01 °CDelivery output of pump max.: 60 liters/minTemperature setting: analogue (continuous)Temperature display: LED bar 3-digitTemperature sensor: analogue (semiconductor)Temperature control: on/off (automatic)Tank capacity max.: 10 litersPower input: 600 WDimension: 260 mm × 320 mm × 220 mmWeight: 8 kg Electronics & Electrical >> Sensors | |
| | | [2008-10-14] for rectal or oral temperature measurement for isolated tissue baths and for Langendorff device stainless steel housing semi-conductor sensorSpecificationsDiameter: 2 or 4 mm Sensitivity: 2.4 mV/°C Factory calibration: 2040 °C Full scale: 20 to +120 °C Electronics & Electrical >> Sensors | |
| | | [2008-10-14] for multipurpose temperature measurement catheter housing semiconductor sensor used for cardiac output device (type CO-101)SpecificationsDiameter: 2 or 4 mmSensitivity: 2.4 mV/°CFactory calibration: 2040 °CFull scale: 20 to +120 °C Electronics & Electrical >> Sensors | |
| | | [2008-10-14] for isolated tissue baths isotonic, auxotonic, isometric applications based on strain gauge high sensitivity no temperature driftSpecificationsInput/ output resistance: 400WSupply voltage: max. 7V DCSuggested supply voltage: 4V DCDiameter: 22 mm Lenght: 75 mmWeight: 220 g Arms maximal deviation: ±10 mmLinearity without pretension: 1% below94% of maximal deviation, 3% aboveForce ranges:Force range: This is the maximum range, that one, in which case the leverage of the sensor can be loaded with weight force.Displacement: its value shows, how much the leverage of the sensor moves when we load it with 1g weight force.Sensitivity: its value shows the voltage value changeability of the sensor in case of a displacement proportional to 1g.loadage.Three measuring sets are used in practice:Isotonic: in this case the displacement of the leverage is 1mm or bigger than that. Auxotonic: if this be the case, the displacement of the leverage can be between 1mm and 500µm. Isometric: if so, Electronics & Electrical >> Others | |
| | | [2008-10-14] experiments on m. extensor digitorum longus, or on m. soleus independent and direct nerve and muscle stimulation one-limb (NM-01) or two limbs (NM-02) option both for rat and mouse easy-to-use investigation pad economically designed self control on the same animal optional DC body heater can be built in on requestDimensionwidth: 250 mm, length: 350 mm,height: 250 mmweight: 2 kg The device offers excellent possibilities to investigate neuromuscular conduction in "in-vivo" conditions on rats. Following anesthesia n. ischiadicus and tendon of the selected muscleis prepared.The knee is fixed in the holder and the contraction force can be measured, applying electrical stimulation either on the nerve or on the muscle. The accurate position of the stimulator electrodes and also the force measuring sensors can be adjusted with the help of the built in manipulators and can be fixed in a preferred position.With the "two legs" system both legs can be fixed on the desk and Electronics & Electrical >> Sensors | |
| | | [2008-10-14] HAAS type brain slice chamber excellent device for studying synaptic transmission in physiology or pharmacology suitable both for extra cellular and intracellular signal detection superfusion with ACSF record of large population of spikes from pyramidal layer of CAI region extracellular amplifier can be used with several types of electrodes (glass, tungsten, Ag/AgCl, etc...)BSS-01 tissue bath (Haas type) is designed to perform electric biopotential measurement extra-, or intracellularly on isolated brain slice samples. The bath is mounted on a base plate, which is equipped with holder for AM-04 manipulator. It holds electrodes for electrical stimulation. The lower plexi glass chamber is filled with distilled water and bubbled with carbogen. The upper plexi glass chamber supports the slice. Temperature is kept constant by a regulated heater placed in the lower plexi glass chamber. A small upper lid covers the upper plexi glass chamber. This lid directs the flow of warmed, moisturized an Electronics & Electrical >> Sensors | |
| | | [2008-10-14] for small mammalian hearts (mouse, rat, hamster, rabbit) working (Neely) and non-working (Langendorff) options in one device pacing possibility control of LVDP, coronary flow and cardiac output by varying the left atrial filling pressure and the hydrostatic pressure in the aorta measurement of heart rate, atrial and ventricular pressure, cardiac output ports for drug administration ports for sensor connections tissue can be quickly frozen for biochemical investigationsThe Neely type working heart model is preferred in such cases, when achieving a higher level of mechanical activity and measurement of external work performance is necessary.Experimetria Neely type working heart perfusion device is the combination of classical Langendorff (non-working) and the Neely type (working) options. As a new development both for WHN-01 and LF-01 setups a special ECG sensor is available. DimensionsWidth: 600 mmLength: 800 mmHeight: 2550 mmWeight: 80 kg Electronics & Electrical >> Sensors | |
| | | [2008-10-14] TSZ-02/1 mainly for educational purposes TSZ-02 classical bath system for tissue strips or rings 5, 10, 20ml chamber volumes automatic overflow adjustable carbogen bubbling built-in field or point stimulation electrodes easy, comfortable operation chamber volume calibration built-in field or point stimulation built-in oxygenizator manual buffer wash-out / emptying internal thermostationTSZ-02 and TSZ-02/1 Isolated Tissue Bath Systems are classical organ bath products for "in vitro" investigations of tissue strips or rings of Experimetria Ltd.These systems offer a handy, comfortable operation from the control of buffer in-, and outflow through the precision bubbling of carbogen to the easy tissue preparation, stimulation facility as well as to easy calibration of chamber volume. The temperature is kept with 0.1?? accuracy in the container. The bath can be connected to a circulating pump (TSZ-02A), which provides more stable (0.01??) temperature maintenance. As the bath is not equipped w Electronics & Electrical >> Others | |
| | | [2008-10-14] implantable manufactured in three different sizes arched shape with suture-holeSpecificationsInput/ output resistance: 540WSupply voltage: max. 5V DCSuggested supply voltage: 2V DCMeasuring range: 0400 gNon-linearity: 5%Dimension: small 5 x 10 mmmedium 6 x 15 mmlarge 9 x 17 mm Electronics & Electrical >> Sensors | |
|