hoch
|
|
|
|
|
 |
 |
| | | [2006-04-09] Technical parameters:
1) Rated voltage: AC 220V, 50Hz
2) Specifications: 1.5(6)A, 2.5(10)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
3) Accuracy: Class1, Class2
4) Operating temperature: -20 ~ +55oC
5) Power loss: =1.0W
6) Pulse drive capacity: not less than 20mA
7) Starting current: =0.004Ib
8) Executive standards: GB/T17215-2002
Functions and features:
1) The meter adopts large-scale compositive circuits and advanced SMT technic of full-
automatic patch welding, designed and manufactured with high quality electronic
components and superior structure material
2) With strict, mature and reasonable testing, debugging technic and management,
so that it can efficiently guarantee the meter running accuracy in measurement,
firmly in structure, and long life motion of requirement. Basic configuration are
ADE7755Chip, UTX safe gauge capacitor, and ruby electrolysis capacitor Electronics & Electrical >> Electric Power Tools | | | | | [2006-04-09] Technical parameters:
1) Rated voltage: 3 x 220V/380V, 50Hz/60Hz
2) Specifications: 3 x 1.5(6)A
3) Constant: 1,600imp/kW.h
4) Accuracy: active energy 0.5, 1.0
5) Reactive energy: 1.0, 2.0
6) Operating tempeature: -25 ~ +55oC
7) Power loss: =2.0W/phase
8) Starting current: =0.004Ib
9) Daily timing error: =0.5s/d
10) Battery using life: =10 years
11) Period of time error: =1min
Electronics & Electrical >> Electric Power Tools | | | | | [2006-04-09] Technical parameters:
1) Rated voltage: AC 200V, 50Hz
2) Specifications: 2.5(10)A, 5(20)A, 10(40)A, 15(60)A
3) Accuracy: Class1, Class2
4) Working temperature range: -20 ~ +55oC
5) Power loss: =1.5W
6) Starting current: =0.004Ib
7) Executive standards: GB/T17215-2002 and GB/T18460.3-2001
Functions and features:
1) Remind to purchase electricity. When the residual electricity quantity close to
overdraft sum, meter will alarm. The alarm's electric quantity value and mode can
be set up agilely according to actual need
2) Digital display of various data, the function of returning display is easy for power
supply department to manage
3) With the function of preventing electricity from stealing to realize the reliable guards
against stealing the electricity truly
4) Particular design of preventing meter crash and many reworking process to protect
meter safety working
5) Presell electricity; auto-cut down power when running out, can setup one overdraft
Electronics & Electrical >> Electric Power Tools | | | | | [2006-04-09] Technical parameters:
1) Rated voltage: AC 220V, 50Hz
2) Specifications: 2.5(10)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
3) Accuracy: Class1, Class2
4) Working temperature range: -20 ~ +55oC
5) Power loss: =1.5W
6) Starting current: =0.004Ib
7) Day time error: =0.5s/d
8) After cut off power, the batteries keep time: =10 years
9) Period of time switching error: =1min
10) Executive standards: GB/T17215-2002, GB/T15284-94, and DL/T645-1997
Functions and features:
1) Measuring functions:
a) May measure single-phase positive and reverse electric power at programming
period of multi-tariffs
b) Measures accurately single-phase positive direction and reverse direction electric
power, and retain the data
2) Tariffs and period:
a) Meter has 32 daily periods, program 2 tariffs of positive and reverse in 24 hours,
even 32 daily periods
b) The meter has 2 tariffs: peak and off-peak
c) Has all ages calendars and makes time to l Electronics & Electrical >> Electric Power Tools | | | | | [2006-04-09] Technical parameters:
1) Rated voltage: 3 x 220V/380V, 50Hz/60Hz
2) Specifications: 3 x 1.5(6)A, 3 x 5(20)A, 3 x 10(40)A, 3 x 15(60)A, 3 x 20(80)A,
3 x
30(100)A
3) Accuracy: Class1
4) Working temperature range: -25 ~ +55oC
5) Power loss: =2.0W/phase
6) Starting current: =0.004Ib
7) Day time of error: =0.5s/day
8) After the power cut off, the batteries keep =10 years
9) Period of time switch error: =1min
10) Executive standards: GB/T17215-2002, GB/T15284-2002, and DL/T645-1997
Electronics & Electrical >> Electric Power Tools | | | | | [2006-04-09] Specifications:
1) Circuit: AC 50Hz / 60Hz
2) Rated working voltage: 660V / 380V
3) Rated working current up to 95A
4) Can switch on and off a remote circuit, protecting it from eventual overload
5) Suitable for frequent start and control of AC motor
6) Pick-up voltage: 85 - 110% (US)
7) Release voltage: 20 - 75% (US) Electronics & Electrical >> Contactor | |
|
|
 |
 |
|
 |
 |
|
 |
|
|
|